Class 12 Physics Chapter 7: Alternating Current Notes Hinglish mein
Ye chapter 5 lines mein
Alternating voltage v = v_m sin ωt usi frequency ka current chalata hai. Resistor mein current v ke saath phase mein hota hai; inductor mein π/2 peeche (X_L = ωL); capacitor mein π/2 aage (X_C = 1/ωC). Series LCR circuit mein Z = √(R² + (X_C − X_L)²), resonance ω₀ = 1/√(LC) par aata hai, aur average power VI cos φ hai. Transformer voltage ko turns ke ratio mein badalta hai.
Ye chapter kis baare mein hai?
Chapter 3 ke circuits cells ke direct current par chalte the: current ek hi direction mein rehta tha. Ghar ki supply alag hai. Uska voltage sine curve ki tarah badhta-ghat-ta hai, ek second mein kai baar ulta hota hai, aur jo current wo chalata hai wo bhi ulta hota hai. Ise alternating voltage aur alternating current kehte hain, chhote mein ac. Zyada tar electrical energy ac ke roop mein banti aur baanti jaati hai, khaas taur par isliye ki transformer ac voltage ko aasaani se aur kam loss ke saath badha ya ghata sakta hai, jisse lambi doori tak bhejna bhi sasta padta hai.
Chapter dekhta hai ki ac voltage v = vm sin ωt ko resistor, inductor, capacitor, aur teeno ko series mein jodne par kya hota hai. Do tools kaam aate hain: rms value, jisse ac power dc power jaisi likhi ja sakti hai, aur phasor, ek ghoomta arrow jo phase ka hisaab rakhta hai. Aakhir mein power, power factor aur transformer aate hain. Circuit diagram mein ac source ka symbol ek circle hai jiske andar chhoti si wave bani hoti hai.
Safety: is chapter mein 220 V, 50 Hz ki ghar ki supply sirf worked examples mein numbers ke roop mein aati hai. Mains socket, wiring ya appliance ko kabhi mat chhuo, mat kholo, aur unse experiment mat karo. Class mein ac ka koi bhi demonstration school lab ke low-voltage ac source se, aur sirf teacher ke saath hota hai.
Resistor par ac lagane se kya hota hai?
Resistor R par v = vm sin ωt lagao. Kirchhoff ka loop rule vm sin ωt = iR deta hai, to
i = im sin ωt, jahan im = vm/R
Ye Ohm ka law hai, aur ac par bhi waise hi chalta hai jaise dc par. Voltage aur current ek hi pal mein peak, zero aur trough par pahunchte hain: wo phase mein hain.
Ek cycle mein current aadhe time positive aur aadhe time negative rehta hai, to uska average zero hai. Par heating zero nahi hai, kyunki wo i² par depend karti hai, jo kabhi negative nahi hota. Kisi pal ki power p = im²R sin² ωt hai, aur ek cycle mein sin² ωt ka average ½ hai. To average power
P = ½ im²R
Ise dc wale roop P = I²R mein likhne ke liye root mean square (rms) ya effective current define karte hain:
I = im/√2 = 0.707 im
aur isi tarah rms voltage V = vm/√2. Phir V = IR aur P = VI = I²R = V²/R, bilkul dc ki tarah. Rms current wo steady current hai jo resistor ko utni hi average rate se garam kare. Ac meters aur ratings rms values dete hain: ghar ka 220 V rms value hai, jiska peak √2 × 220 ≈ 311 V hai. 220 V ke liye rated 100 W bulb (Example 7.1) ka R = 220²/100 = 484 Ω hai aur wo I = 100/220 ≈ 0.45 A leta hai. Padho resistor, inductor aur capacitor mein AC.
Phasors kya hain?
Inductor ya capacitor ke saath current aur voltage saath-saath peak nahi karte. Aise phase differences dikhane ke liye book phasors use karti hai. Phasor ek arrow hai jo origin ke around ω angular speed se anticlockwise ghoomta hai. Uski length peak value (vm ya im) hai, aur kisi bhi pal vertical axis par uska projection us pal ki value (jaise vm sin ωt) hai. Saath ghoomte do phasors ke beech ka angle fixed rehta hai, aur wahi phase difference hai. Resistor ke liye voltage phasor V aur current phasor I har pal ek hi line par hote hain: phase difference zero.
Voltage aur current scalars hain, vectors nahi. Phasors sirf isliye use hote hain ki ek hi frequency ki sine quantities theek usi tarah judti hain jaise ghoomte arrows ke projections, to vector jodne ka jaana-pehchana rule kaam kar deta hai.
Inductor ac ke saath kya karta hai?
Nahin ke barabar resistance wale inductor L par v = vm sin ωt lagao. Loop rule v − L di/dt = 0 deta hai; doosra term self-induced emf hai jo badlaav ka virodh karta hai (Lenz ka law, Chapter 6, Electromagnetic Induction se). To di/dt = (vm/L) sin ωt. Integrate karke, aur constant zero lekar kyunki current zero ke around barabar jhoolta hai,
i = im sin(ωt − π/2), jahan im = vm/XL aur XL = ωL
XL inductive reactance hai. Ye ohm mein naapa jaata hai, resistance ki tarah current ko rokta hai, aur L aur frequency dono ke saath badhta hai. Current voltage se π/2 peeche hai: quarter period baad peak karta hai. Kisi pal ki power −½ imvm sin 2ωt aati hai, jiska cycle par average zero hai. Pure inductor ek quarter cycle mein energy leta hai aur agle mein lauta deta hai. Example 7.2: 50 Hz par 25.0 mH ka XL = 2π × 50 × 0.025 = 7.85 Ω, to 220 V se 220/7.85 = 28 A chalta hai.
Capacitor ac ke saath kya karta hai?
Dc par capacitor tabhi tak current bahne deta hai jab tak charge na ho jaaye. Ac par voltage ulat-ta rehta hai, to capacitor baar-baar charge aur discharge hota hai aur current chalta rehta hai. v = q/C = vm sin ωt se current i = dq/dt = ωCvm cos ωt hai, yaani
i = im sin(ωt + π/2), jahan im = vm/XC aur XC = 1/ωC
XC capacitive reactance hai, ye bhi ohm mein, par frequency ya capacitance badhne par ghat-ta hai. Current voltage se π/2 aage hai, quarter period pehle peak karta hai. Inductor ki tarah cycle par average power zero hai. Example 7.4: 50 Hz par 15.0 µF ka XC = 1/(2π × 50 × 15.0 × 10⁻⁶) = 212 Ω, to 220 V se rms current 1.04 A (peak 1.47 A). Frequency dugni karne se XC aadha aur current dugna hota hai.
Series LCR circuit kaise hal hota hai?
R, L aur C ko source ke saath series mein lagao. Teeno mein ek hi current behta hai, i = im sin(ωt + φ), jahan φ source voltage aur current ke beech ka phase angle hai. Loop rule L di/dt + Ri + q/C = v hai. Har pal vL + vR + vC = v, par teeno voltages alag-alag time par peak karte hain, to unke amplitudes phasors ki tarah jodne padte hain:
- VR (length imR) I ke saath hai;
- VL (length imXL) I se π/2 aage hai;
- VC (length imXC) I se π/2 peeche hai.
VL aur VC ulti directions mein hain aur milkar |vCm − vLm| length ka ek phasor bante hain. Ye VR ke perpendicular hai, to Pythagoras se vm² = (imR)² + (imXC − imXL)², yaani
im = vm/Z, jahan impedance Z = √(R² + (XC − XL)²)
aur tan φ = (XC − XL)/R. Ye dono results impedance diagram mein dikhte hain, ek right triangle jiska hypotenuse Z hai. Agar XC > XL, to φ positive: circuit zyada capacitive hai aur current aage hai. Agar XC < XL, to φ negative: circuit zyada inductive hai aur current peeche hai. Phasor method steady-state solution deta hai; switch on karne ke turant baad ek transient hissa bhi hota hai jo khatam ho jaata hai. Padho series LCR circuit aur resonance.
Resonance kya hai?
Jo system kisi natural frequency par jhoolna chahta hai, use usi frequency par dhakka diya jaaye to wo zor se react karta hai, jaise jhoola apni chaal ke saath dhakka milne par. Series LCR circuit bhi aisa hi hai. ω badalne par XL badhta hai aur XC ghat-ta hai; ek frequency ω₀ par dono barabar hote hain, impedance apni sabse chhoti value Z = R par aa jaata hai, aur current amplitude sabse bada, im = vm/R. ω₀L = 1/(ω₀C) se,
ω₀ = 1/√(LC) (resonant frequency)
L = 1.00 mH aur C = 1.00 nF ke liye ω₀ = 10⁶ rad/s. vm = 100 V ke saath peak current R = 100 Ω par 1.0 A aur R = 200 Ω par 0.5 A hai. Resonance ke liye L aur C dono chahiye, kyunki tabhi dono reactive voltages cancel ho sakte hain; RL ya RC circuit mein resonance nahi hoti. Radio aur TV tuning isi par chalti hai: knob ghumane se ek capacitance badalti hai jab tak ω₀ chahe gaye station ki frequency se na mil jaaye, aur us station ka current sabse bada ho jaata hai. Metal detector bhi resonance se kaam karta hai (Example 7.10).
Ac circuit kitni power use karta hai?
v = vm sin ωt aur i = im sin(ωt + φ) ke saath kisi pal ki power p = ½vmim[cos φ − cos(2ωt + φ)] hai. Doosre term ka average zero hai, to average power
P = VI cos φ = I²Z cos φ
cos φ ko power factor kehte hain. Chaar cases:
- Pure resistor: φ = 0, cos φ = 1, aur di gayi V aur I ke liye power sabse zyada.
- Pure inductor ya capacitor: φ = ±π/2, cos φ = 0, to current behne par bhi koi power use nahi hoti. Ye wattless current hai.
- RL, RC ya LCR circuit: φ inke beech, aur power sirf resistor mein use hoti hai.
- Resonance par LCR: XC − XL = 0, φ = 0, cos φ = 1, aur us circuit ke liye P = I²R sabse zyada.
Example 7.8 mein (R = 3 Ω, XL = 8 Ω, XC = 4 Ω, 50 Hz par peak 283 V) Z = 5 Ω, φ = −53.1°, rms current 40 A, power 40² × 3 = 4800 W aur power factor 0.6. Power lines mein kam power factor mehenga padta hai: usi voltage par utni hi power ke liye current bada chahiye, aur line loss I²R badh jaata hai. Parallel mein juda capacitor current ke lagging, wattless hisse ko cancel karke power factor ko 1 ki taraf le jaata hai (Example 7.7).
Transformer kaise kaam karta hai?
Transformer mutual induction (Chapter 6) se ac voltage ko bada ya chhota karta hai. Do insulated coils, primary (Np turns) aur secondary (Ns turns), soft iron ke ek core par hote hain; ek ke upar doosra ya do alag limbs par. Primary ka ac core mein alternating flux φ banata hai, jo dono coils ke har turn se guzarta hai. Ideal transformer (windings ka resistance nahi, flux leak nahi, secondary current chhota) mein har turn ka emf dono coils mein barabar hai, to
Vs/Vp = Ns/Np
Agar energy waste na ho, IpVp = IsVs, to Is/Ip = Np/Ns. Ns > Np ho to step-up transformer (zyada voltage, kam current); Ns < Np ho to step-down. 100 primary aur 200 secondary turns ke saath 10 A par 220 V, 5.0 A par 440 V ban jaata hai. Voltage badhane se energy paida nahi hoti: current usi ratio mein ghat jaata hai. Padho transformer kaise kaam karta hai.
Asli transformers thodi energy kho dete hain: flux leakage, windings ka resistance, core mein eddy currents (core ko laminate karke kam), aur core mein hysteresis. Book batati hai ki achhi tarah design kiya transformer 95 per cent se zyada efficient ho sakta hai.
Is chapter ki quantities aur units kaun si hain?
- rms voltage V aur rms current I: volt aur ampere; V = vm/√2, I = im/√2.
- Reactances XL = ωL aur XC = 1/ωC, aur impedance Z: ohm, dimensions [M L² T⁻³ A⁻²].
- Resonant angular frequency ω₀ = 1/√(LC): rad s⁻¹, dimensions [T⁻¹]; hertz mein ν₀ = ω₀/2π.
- Power factor cos φ: koi unit nahi.
- Quality factor Q = ω₀L/R = 1/(ω₀CR): koi unit nahi. Book ise quantities ki table mein deti hai, par iska koi section nahi hai. (Extra: Q jitna bada, resonance peak utna patla aur tez.)
Aage badhne se pehle
Chaar ideas chapter ko chalate hain. Rms values ac power ko dc power jaisa bana deti hain. Phasors phase differences ko arrows ke beech ke angles mein badal dete hain. Reactances aur impedance resistance ka kaam karte hain, Z = √(R² + (XC − XL)²) aur resonance ω₀ = 1/√(LC) par. Energy sirf resistance use karta hai, P = VI cos φ, aur transformer turns ke ratio mein voltage ke badle current deta hai. Saari 8 exercises aur saare 10 worked examples Chapter 7 ke NCERT solutions mein hal kiye gaye hain.
Key terms (zaroori shabd)
| Term | Matlab |
|---|---|
| Alternating voltage (ac voltage) | Aisa voltage jo time ke saath sine wave ki tarah badalta hai, v = v_m sin ωt; v_m uska amplitude (peak value) aur ω angular frequency (ω = 2πν) hai. |
| rms (effective) value | Wo steady (dc) value jo utni hi average heating de. Sine wave ke liye I = i_m/√2 ≈ 0.707 i_m aur V = v_m/√2. Meters aur ratings rms values batate hain. |
| Phasor | Origin ke around ω angular speed se ghoomta vector. Uski length voltage ya current ki peak value hai; vertical axis par uska projection us pal ki value hai. |
| Inductive reactance (X_L) | X_L = ωL, pure inductor ka ac ke against rukaav. Unit ohm. Ye frequency ke saath barabar ratio mein badhta hai. |
| Capacitive reactance (X_C) | X_C = 1/ωC, capacitor ka ac ke against rukaav. Unit ohm. Frequency badhne par ye ghat-ta hai. |
| Impedance (Z) | Series LCR circuit ke liye Z = √(R² + (X_C − X_L)²), taaki i_m = v_m/Z. Unit ohm. |
| Phase angle (φ) | i = i_m sin(ωt + φ) mein wo angle jitna current source voltage se aage hai; tan φ = (X_C − X_L)/R. |
| Resonance | Series LCR circuit mein X_L = X_C wali condition. Ye ω₀ = 1/√(LC) par hoti hai; tab Z = R aur current amplitude sabse bada hota hai. |
| Power factor | Average power P = VI cos φ mein cos φ. Pure resistor ke liye 1 aur pure inductor ya capacitor ke liye 0. |
| Wattless current | Aisa current jo behta hai par koi average power use nahi karta, jaise pure inductor ya capacitor mein (cos φ = 0). |
| Transformer | Soft-iron core par do coils (primary N_p turns, secondary N_s turns). Ye mutual induction se ac voltage badalta hai: V_s/V_p = N_s/N_p. |
| Step-up aur step-down | N_s > N_p wala transformer voltage badhata hai (aur current ghatata hai); N_s < N_p wala voltage ghatata hai (aur current badhata hai). |
Is chapter ke topics
Practice karo
-
Jis ac voltage ki rms value 220 V hai, uski peak value lagbhag hai:
Jawab dekho
Jawab: (c) 311 V
-
Ac source se jude pure inductor mein current:
Jawab dekho
Jawab: (c) voltage se π/2 peeche hai
-
Source ki frequency dugni karne par capacitive reactance:
Jawab dekho
Jawab: (b) aadha hota hai
-
Series LCR circuit mein resonance par impedance hai:
Jawab dekho
Jawab: (b) R ke barabar
-
Ek cycle mein pure capacitor dwara use ki gayi average power hai:
Jawab dekho
Jawab: (d) zero
-
Transformer ke primary mein 100 aur secondary mein 500 turns hain. Primary par 20 V ho to secondary voltage hai:
Jawab dekho
Jawab: (c) 100 V
Students ke sawal
Class 12 Physics Chapter 7 ke main topics kya hain?
Resistor par ac voltage aur rms value, phasors, inductor aur capacitor par ac voltage (reactance aur phase), phasor diagram se hal kiya series LCR circuit (impedance, phase angle aur resonance), ac circuit mein power aur power factor, aur transformer.
Kya LC oscillations 2026-27 ki Class 12 Physics book mein hain?
Nahi. Physics Part I (Reprint 2026-27, pages 177 se 200) ke rationalised Chapter 7 mein LC oscillations ka koi section nahi hai, aur sharpness of resonance par bhi text nahi hai; sirf quantities ki table mein quality factor Q likha hai. Exercise 7.6 phir bhi LC circuit ke free oscillations ki angular frequency poochhta hai, jo wahi formula ω₀ = 1/√(LC) use karta hai.
Is chapter ke kaun se formulas yaad rakhne chahiye?
I = i_m/√2 aur V = v_m/√2; X_L = ωL aur X_C = 1/ωC; Z = √(R² + (X_C − X_L)²) aur i_m = v_m/Z; tan φ = (X_C − X_L)/R; ω₀ = 1/√(LC); P = VI cos φ = I²Z cos φ; aur transformer ke liye V_s/V_p = N_s/N_p aur I_s/I_p = N_p/N_s.
Inductor ya capacitor power kyun use nahi karte?
Dono mein current aur voltage ke beech quarter cycle ka farq hota hai. Cycle ke ek quarter mein element source se energy leta hai aur store karta hai (L mein magnetic field mein, C mein electric field mein), aur agle quarter mein poori wapas de deta hai. Poore cycle ka average zero aata hai.
Lambi lines par electric power high voltage par kyun bheji jaati hai?
Di gayi power P = VI ke liye zyada voltage ka matlab kam current, aur line mein heat loss I²R hai. Generator ke paas step-up transformer voltage badhata hai, aur users ke paas step-down transformers use phir ghatate hain.
Koi sawal atak gaya?
Photo lo, Lagnever AI step-by-step samjhayega. 7 din ka trial sirf ₹2.
Google Play se app lo Browser mein kholo
Parents ke liye: trial ke baad plan har mahine UPI ya card autopay se renew hota hai. App mein kabhi bhi cancel kar sakte hain.